ME 5400 RL - Signal conditionner/amplifier

ME 5400 RL - Signal conditionner/amplifier
    Designed for strain gages sensors Format EUROPE Card version : ME 5400 Front rack panel : ME 5400 RL Front rack casing : MR 5400 CRL Constant sensor voltage excitation Adjustable gain with range switch and 10 turn potentiometer, located on front panel from 10,000 to 30,000 Analog output control with BCN on front panel. Adjustable balance with 10 turn potentiometer ans led control of zero. Shunt reference integrated. High stability bridge complement for 1/4 bridge, 1/2 bridge, 120 and 350 ohms and full bridge. Precision 0.05%

The ME 5400 conditionneur is designed for static measurement and/or dynamic measurement from 1/4, 1/2 or full bridge, or large range gages sensor ( pressure, load, torque, displacement)
The format EUROPE allows for an easy existing rack installation.

Technical specification
Excitation voltage V ± 15 ± 1 V
Sensor excitation voltage Adjustable from 4 to 12 V régulated 10-5 (factory setup at 10V)
Band pass 0-15 KHz on maximum gain(factory setup at 500 Hz)
Consumption mA from ±70 to ±150 depending on options
Calibration reference resistor With counter voltage 1 mV/V or 10 mV/V precision 5.10-4 oo shunt
Input resistance Ohm >= 10 power 12
Zero range Standard gages ± 0,5mV/V Semi conductor ±5mV/V
electrical installation DIN 41612 connector - 2X32 pins
Output signal Vdc ±10 (20 mA maximum)
Operating temperature °C 0 to +50
Storage temperature -10 to +70°C