The LX-PA series sensor allows for a precise measurement from 0-50mm to 0-1,250m ranges.
The moving part is attached to the cable end, while the body is fixed. The cable movement pulls a spring attached to a potentiometer. The cable spring maintain a constant pull back tension on the cable. The pull back speed is limited by the spring torque. Installation support option.
| Technical specification | ||
|---|---|---|
| Excitation voltage | VAC ou DC | 25 maxi |
| Linearity deviation | %EM | +/- 1 for capacity <=120 mm +/- 0,5 for capacity 250 625 mm +/- 0,25 for capacity 750 1250 mm |
| Capacity | mm | 50, 70, 96, 120, 250, 380, 500, 625, 750, 1000, 1250 |
| Moisture | %HR | 95 maxi |
| Input resistance | Ohm | 1,000 +/- 15% |
| Output resistance | Ohm | 0 to 1,000 |
| Mass | g | 85 |
| Material | Plastic case | |
| Operating temperature | °C | -15 to +60 (5°F to 140°F) |
| Storage temperature | -25 to +80 (-13°F to 176°F) | |
Installation support
Input impedence 2 to 5 kohms
| Modèle | Etendue de Mesure (mm) | Sensibilité mV/V/mm | Effort de rappel sur câble (N) |
| LX-PA-2 | 50 | 18.5 | 4.4 |
| LX-PA-2.8 | 70 | 13.4 | 3.9 |
| LX-PA-3.8 | 96 | 10.1 | 3.1 |
| LX-PA-4.7 | 120 | 8.1 | 2.2 |
| LX-PA-10 | 250 | 3.5 | 4.4 |
| LX-PA-15 | 380 | 2.5 | 3.9 |
| LX-PA-20 | 500 | 1.9 | 3.1 |
| LXPA-25 | 625 | 1.5 | 2.2 |
| LX-PA-30 | 750 | 1.3 | 3.9 |
| LX-PA-40 | 1000 | 1.0 | 3.1 |
| LX-PA-50 | 1250 | 0.8 | 2.2 |