The BICM conditionner module allows for a VDC input with a position proportional output signal relative to the zero middle point
Version free shaft: The play between the shaft and the sensor body allows for a movement without contact
Version guided shaft: When a more rigid design is requiered, self libricated sleeves are inserted. This version is necessary if the sensor is equiped with a spring loaded shaft.
Version high temperature: Standard sensor are designed for -55°C +150°C (-67°F to 300°F), the high temperature version is designed for 200°C (392°F)
| Technical specification | ||
|---|---|---|
| Excitation voltage | V | ± 15 dc with BICM |
| Consumption | mA | 8 to 12 |
| Linearity deviation | %EM | 0.5 with BICM |
| Capacity | mm | ±1,5. ±2,5. ±5. ±7,5. ±10. ±15. ±25. ±50. ±75. ±100. ±125 |