The series position sensors LIPS 101 are high precision, robust devices designed for industrial environment. A signal amplifier-conditioner in included giving a high level output. The inductive technology allows for a high band pass above 500Hz.
| Technical specification | ||
|---|---|---|
| Precision class | %EM | +/- 0.5 |
| Consumption | mA | 20 maxi |
| Capacity | mm | 50, 100, 200, 300, 400, 500, 600 |
| MTBF | Heures | 450,000 at 40°C (104°F) |
| Operating temperature | °C | -20 to +85 (-4°F to 185°F) |
| Storage temperature | -40 +125°C | |
| Admissive shock | g | 40 (IEC 68-2-29) |
| Vibration resistance | g | 10 (IEC 68-2-6) |
SENSOR REFERENCE :
LIPS 101-EM-(A, B, C, D ou E)-X-Options
Remplace X with :
I : Side output cable IP 67 and length in cm
J : Axial Connector Hirschmann IP 65
K : Side Hirschmann IP 67
L : Axial cable IP 65 and length in cm
| Alimentation | Signal de sortie | Référence |
| 5 VDC +/- 1 VDC | 0,5 4,5 VDC | LIPS 101-EM-A |
| +/- 15 VDC | +/- 5 VDC | LIPS 101-EM-B |
| +/- 15 VDC | +/- 10 VDC | LIPS 101-EM-D |
| 16 28 VDC | 0,5 9,5 VDC | LIPS 101-EM-C |
| 16 28 VDC | 4...20 mA (2fils) | LIPS 101-EM-E |