The pedal load DAC 2000 P series are designed to measure loads on break or clutch pedals. The 2 points central support makes the device independent from the load point.
| Technical specification | ||
|---|---|---|
| Sensitivity creep on compensated range | %/°C | < 0.06 |
| Zero creep on compensated range | %Em/°C | < 0.015 |
| Hysteresis deviation | %EM | <= ± 0.2 |
| Linearity deviation | %EM | <= ± 0.2 |
| Capacity | daN | 20, 50, 100, 150 |
| Input resistance | Ohm | 350 |
| Output resistance | Ohm | 350 |
| Electrical insulation | MOhm | > 5000 |
| Material | Aluminium alloys | |
| Sensitivity at full range | mV/V | 1.5 ± 10% |
| Safe overload | %EM | 150 |
| Operating temperature | °C | -10 to +60 (14°F to 140°F) |
| Compensated temperature | °C | +10 to +60 (50°F to 140°F) |
| Excitation voltage | V | 10 |
DAC 2000P-2D ( 2 measuring axes)
Fx = 50, 100, or 150 daN
Fy = 25 or 50 daN
Output on 4 conductor cable 2 meter length
(other length upon request)
| Câble | |
| Rouge | + Alimentation |
| Bleu | - Alimentation |
| Jaune | + Mesure |
| Blanc | - Mesure |