The PM 104 TE series pressure sensor with an out of body electronic device allow through its compact size and diaphragm design to be inserted close to the pressure point with temperature up to +200°C (+390°F)
| Technical specification | ||
|---|---|---|
| Tightening torque | Nm | de 1.2 to 1.5 |
| Sensitivity creep on compensated range | %/°C | +/- 0.007 |
| Zero creep on compensated range | %Em/°C | +/- 0.007 |
| Initial imbalance | %Em | +/- 5 |
| Linearity & hysteresis deviation | % EM | 0.5 |
| Capacity | bars | 5, 10, 20, 50, 100, 200, 250, 400 |
| Material | Titanium (5bar) Stainless steel (other ranges) | |
| Electric cable specification | Teflon jacket | |
| Hydraulic installation | Ø M10 pitch 100 | |
| Output signal | Vdc | 2.5 to 7.5 |
| Safe overload | %EM | 150 |
| Operating temperature | °C | Sensor : -50 to +200 (-60°F to 390°F) Electronic : 0 to +80 (32°F to 175°F) |
| Excitation voltage | V | 12 +/- 4 |
Other output signal
Other measuring ranges
Output 4 conductor braided cable, length 1 meter between sensor and electronics and 1 meter length behind electronic device
| Câble | |
| Rouge | + Alimentation |
| Blanc | - Alimentation |
| Jaune | + Mesure |
| Bleu | - Mesure |