The PI 104 series pressure sensors are manufactured in stailess steel. The diaphragm located at the end of a 1/4 gaz or M20 pitch 100 thread allows for reduced dead volume
| Technical specification | ||
|---|---|---|
| Sensitivity creep on compensated range | %/°C | ± 0.02 |
| Zero creep on compensated range | %Em/°C | ± 0.02 |
| Initial imbalance | %Em | ± 2 |
| Hysteresis deviation | %EM | ± 0.25 |
| Linearity deviation | %EM | 0.25 |
| Capacity | bars | 10, 25, 50, 100, 250, 350, 500 |
| Input resistance | Ohm | 350 |
| Output resistance | Ohm | 350 |
| Electrical insulation | MOhm | > 1000 under 40 V |
| Material | Stainless steel | |
| Hydraulic installation | Ø M20 pitch 100 or 1/2 gaz cylindrical | |
| Sensitivity at full range | mV/V | 1.5 to 2 |
| Safe overload | %EM | 150 |
| Operating temperature | °C | - 20 to + 100 (-4°F to 210°F) |
| Excitation voltage | V | 10 |
Out of standard catalog range
Shunt calibration included
Output with direct cable connection
Hight temperature T1 : 120 ° C
Hight temperature T2 : 150 ° C
To fully take advantage of the diaphragm design, the sensor must be installed as close as possible from the desired measuring point to avoid dead volume. Use a flat seal type BS under Ø 22
Output through base connector Jaeger 43082 (Male plug and cord grip included)
| Prise | |
| 1 | + Alimentation |
| 3 | - Alimentation |
| 4 | + Mesure |
| 2 | - Mesure |