PE 102 series pressure sensors are designed for static and dynamic pressures.
They could be inserted close to the measuring point to avoid dead volumes.
| Technical specification | ||
|---|---|---|
| Sensitivity creep on compensated range | %/°C | ± 0.02 |
| Zero creep on compensated range | %Em/°C | ± 0.015 |
| Initial imbalance | %Em | ± 2 |
| Hysteresis deviation | %EM | ± 0.15 |
| Linearity deviation | %EM | 0.35 |
| Capacity | bars | 5, 10, 25, 50, 100, 250, 350, 500 |
| Input resistance | Ohm | 350 |
| Output resistance | Ohm | 350 |
| Electrical insulation | MOhm | > 1000 under 40 V |
| Material | Stainless steel | |
| Hydraulic installation | Diaphragm design | |
| Sensitivity at full range | mV/V | 1 for 5 bars range 1.5 to 2 for other ranges |
| Safe overload | %EM | 150 |
| Operating temperature | °C | - 20 to + 120 (-4°F to 250°F) |
| Excitation voltage | V | 10 |
Ranges out of catalog
Special temperatures compensations option PE 102
To take full advantage of the diaphragm design, the sensor must be placed as close as possible of the desired measuring point, to avoid dead volume. Use a Ø 23,7mm Oring to seal and tighten the sensor through its upper part.
Output through a 4 wire braided cable. length 1 meter.
Other length upon request
| Version câble | |
| Rouge | + Alimentation |
| Bleu | - Alimentation |
| Jaune | + Mesure |
| Blanc | - Mesure |